The accident in Cam Hung Commune, Cam Xuyen, Ha Tinh caused 4 deaths due to the violation of the grid corridor. Though it happened nearly 2 years ago (October 26, 2018), it is so far a valuable experience for those who intend to violate the safety corridor of the electricity grid or construction works near the unauthorized power line. Tran Phu Electric Mechanical Company will provide readers with the necessary information to ensure the construction and building of projects near power lines safely and legally.
Safe distance during construction and building works near power lines
To ensure the safety of citizens, the government has set up an electrical safety corridor. If the safety distance of this corridor is complied, the risk of an accident while constructing near the power lines will be maximumly limited. The safety grid of the overhead power grid is the space along the line, detailed in the image below:
The distance of the safety corridor of overhead conducting line
EXTRACTED IN DECREE 14 / 2014.NĐ - CP. DAY 26/2/2014 OF VIETNAMESE GOVERNMENT
THE SAFETY CORRIDOR OF THE OVERHEAD ELECTRICAL GRID LINE
HEIGHT LIMITATION
- Insulation voltage up to 35kV is 2m
- Insulation voltage 110kV is 4m
WIDTH LIMITATION
- Supplied voltage up to 22kV, the covered wire is 1m, bare wire is 2m
- The voltage level of 35kV, the covered wire is 1.5m, bare wire is 3m
- The voltage level of 110kv, bare wire is 4m
- Supplied voltage up to 35kV, it is 3m
- The voltage level at 110kV, it is 4m
WIDTH LIMITATION
- Supplied voltage up to 22kV, the covered wire is 1m, bare wire is 2m
- The voltage level of 35kV, the covered wire is 1.5m, this ceiling is 3m
POWER LINES OUT OF THE CITY, TOWN, AND TOWNSHIP
- Supplied voltage up to 35kV shielded wire is 0.7m bare wire is 2m
- The supplied voltage of 110kV bare wire is 3m
VOLTAGE
|
TO 35kV
|
TO 110kV
|
Safe discharge distance
|
4.0m
|
6.0m
|
Regulations on construction and building near power lines
1. Prohibited acts
In Article 4 of Decree No. 14/2014 / ND-CP detailing the implementation of the Electricity Law on Electrical Safety also states: Prohibited acts including climbing on electricity poles, entering power stations or safe areas of electricity works when not on duty; using high-voltage grid works for other purposes without agreement with the unit managing high-voltage grid works.
Strictly forbidden to climb on electric poles
2. Construction permit
In Article 34 of Decree 59/2015 / ND-CP on Construction, Investment Project Management states: Construction contractors must prepare safety measures, equipment, and construction facilities for workers before the construction. In case of safety measures involving many parties, they must be agreed upon by all parties.
Workers equipped full protective clothing such as hats, clothes, shoes for the construction
Related news: Alarming of electricity insecurity
All the regulations, notes of the project construction and building near the power lines are aimed at ensuring the safety of life and property for all of us, therefore, strict observance is what is extremely necessary. Tran Phu electric wire and cable promises to continue to bring readers useful information to be equipped with knowledge about electrical safety in the following articles.